Guard Column cartridges, Bidentate C8 2.o, replacement, 2.0 mm ID x 10 mm long cartridges packed with 2.2 um, 120 A phase. Cogent TYPE-C Brand. 5/PK.

Additional Info:

The 40208‑PG2 Cogent Bidentate C8 2.0 Guard Column Cartridges are replacement cartridges engineered for UHPLC and high‑pressure analytical systems, where maintaining column performance and preventing system contamination is critical.

Each cartridge is:

  • 2.0 mm ID × 10 mm length

  • Packed with 2.2 µm, 120 Å TYPE‑C™ silica hydride Bidentate C8 2.0 phase

  • Constructed in stainless steel hardware with SS frits

Cartridges are individually packaged in protective Delrin™ cases, preventing drying, contamination, or physical damage before installation.

⚠️ Requires guard column holder (sold separately)

Designed for 2.1 mm UHPLC Columns

These cartridges are optimized for:

  • 2.1 mm ID analytical and UHPLC columns

  • Sub‑2 µm particle methods

  • LC‑MS workflows requiring high sensitivity

Proper guard matching ensures:

  • Minimal band broadening despite small particle size

  • Maintained efficiency and resolution

  • Stable retention and reproducibility

Why Use UHPLC Guard Cartridges

UHPLC columns (2.2 µm particles) are highly sensitive to:

  • Particulates and debris

  • Strongly retained contaminants

  • Sample matrix buildup

  • Pressure increases from blockage

The 40208‑PG2 cartridges act as a critical protection layer, helping to:

  • Preserve UHPLC column efficiency

  • Prevent pressure spikes and system clogging

  • Extend analytical column lifetime

  • Maintain consistent high‑resolution results

Cartridges can be replaced quickly without disturbing the analytical column setup.

Bidentate C8 2.0™ Guard Phase Advantages

Using a matched phase ensures:

  • No change in retention or selectivity

  • Seamless analyte transfer

  • No need for method re‑validation

Compared to C18:

  • Reduces excessive hydrophobic retention

  • Improves recovery of amine‑containing compounds

  • Provides alternative selectivity in complex separations

  • Enables faster equilibration in gradient methods

Cogent TYPE‑C™ Technology Benefits

Silica Hydride Surface

  • Reduced silanol activity

  • Improved peak shape for basic analytes

  • Lower secondary interactions

High‑Pressure Stability

  • Designed for UHPLC / sub‑2 µm workflows

  • Compatible with elevated system pressures

  • Maintains performance under demanding conditions

Faster Equilibration

  • Reduced cycle times

  • Increased throughput for high‑efficiency methods

Typical Applications

  • UHPLC and LC‑MS analytical methods

  • Pharmaceutical and bioanalytical workflows

  • High‑resolution separations

  • Complex sample matrices

  • Methods using sub‑2 µm Bidentate C8 columns

 

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media